RTX 8630 User's Guide Page 57

  • Download
  • Add to my manuals
  • Print
  • Page
    / 117
  • Table of contents
  • BOOKMARKS
  • Rated. / 5. Based on customer reviews
Page view 56
SME VoIP System Guide, Version 1.9
Proprietary and Confidential
Chapter: SME VoIP Administration Interface
57
5.13.1.1 Manually
Parameters
Description
RPN
SINGLE CELL SYSTEM:
The base has always RPN00, first repeater will then be RPN01, second repeater
RPN02 and third RPN03 (3 repeaters maximum per base)
MULTI CELL SYSTEM:
Bases are increment by 2^2 in hex, means first base RPN00 second base RPN04
etc., in between RPN01, 02, 03 addressed for repeaters at Primary base and 05,
06, 07 addressed for Secondary base (3 repeaters maximum per base)
DECT sync source
Select the base or repeater the repeater has to be synchronized to.
5.13.1.2 Local Automatical
Repeater controlled by auto detects best base signal and auto assign RPN.
Repeater on base only, repeater on repeater (chain) not supported.
Repeater RPN dynamic assigned in base RPN range.
5.13.2 Register Repeater
Adding a repeater makes it possible to register the repeater. Registration is made by select the repeater
and pressing register repeater. The base window for repeater registration is 5 minutes.